Generac generator runs then shuts off

My generac generator will run for a while, maybe two or three hours then it shuts off. The lights blink 7 times and the - Answered by a verified Technician We use cookies to give you the best possible experience on our website.

Generac generator runs then shuts off. Hi guys, hoping you can help explain what might be wrong with my Generac generator. It's a model 0055060 20kW. We noticed during the last outage that the output voltage was WAY too high on the unit and the lights were very bright. We shut the unit down to prevent any damage to the house. What would cause something like this?

03 - Craftsman Generator Fuel Cap. As fuel is consumed by the engine, the level in the fuel tank lowers. To make up for this, the fuel cap uses a small vent to allow air to enter the tank. If the fuel cap vent is clogged, air won't be able to enter the tank and a vacuum or "vapor lock" will occur. This stops the flow of fuel to the ...

Generac Model OE6219 SERIAL 7888609 Natural Gas. Unit starts and runs in manual mode for about 10 seconds then shuts off the overcrank led is lit ,does this constantly, I could hear the starter motor engaging when it was running so I disconnected the trigger wire from it still shuts down after a few seconds.My Generac 4000 EXL starts well but then only runs for 5-10 seconds and then stops. It seems like it is starved for fuel. It will start right up again and do the same thing. I can do this over and over again until the battery is discharged, It has plenty of oil and the red low oil lamp does not come on. The air filter is clean.RPM Sense Loss, Code 1501/1505/1511/1515 -. If the unit was running and shuts down, attempting to restart, clear the alarm by pressing the ENTER button twice, then press AUTO. Next, remove some of the loads. Try putting it back in AUTO and then restart. If it does not start after doing this, you will need to place a service call.Turn off the generator and let it cool down. Put on gloves and safety goggles. Open up the generator’s cover or panel to get to the carburetor. Spray carb cleaner on all the carb parts. Wait for it to loosen the grime, which usually takes 10 to 15 minutes. Use a brush to scrub away the loosened dirt gently.I have a 15kw generac generator. (0043903) The generator is on propane. It is not hooked up to anything yet. I was giving the generator because it didn't work. I tried to start it with main breaker off. It start and then turned off with over speed light blinking. What do you think? Item # 0043903 serial # 4223907After replacing the spark plug, run the generator again to see if the issue is resolved. 4 . Blockage in the Air Filter. A blockage in the air filter can cause your Firman generator to shut off after running for about 20 minutes. When the air filter is blocked or dirty, it can prevent the necessary air from reaching the combustion chamber.1998 Rexair motor home with a Generac Model #GN480 Q55G serial#301011. Starts easy, runs great for about 1 to 2 minuets, then shuts off. Not low on oil. Generator will run as long as I have 12 volts a … read more

This is a microprocessor controlled genset, and will store a fault code when it shuts down. Let's see what code is set. Go to the genset and use the switch on the set itself. Press 'Stop' 3 times within 5 seconds. The light in the switch will start flashing. If the light flashes 3 times, pauses for 3 seconds, and flashes 3 more times, press and ...Before the generator's engine starts, there is no oil pressure. The oil. sensor is ignored until the engine has a chance to come up to speed. If. it then shuts down, it normally indicates a low oil level. If you are sure there is enough oil, disconnect the wire to the oil. sensor and see if the engine keeps running.I purchased this generator the end of December so its only about 3 months old. Use it daily and it was running fine and then shut off. Tried restarting it after checking oil level and fuel levels. It starts but will not stay running...runs for about 10 seconds and shuts off. I have replaced spark plug, fuel filters air filter and carburator.The generator may have shut down because of overload, which can damage its internal components. In this situation, you need to reset the circuit breakers and power fewer appliances with it. If the problem is not resolved, then there may be something wrong with the generator itself.I have a Generac generator 7550, with a Guardian OHVT Engine model GH-410, 13/15 hp. The generator starts (electric) and runs for 1o to 15 seconds and then the engine shuts down. I have cleand the fue … read moreHowever, when the power goes off I don't always want to run it 24/7. Usually, I'll turn it off for 3-4 hours until I need the recharge the well pump, refrigerator/freezer and heating systems so I may run it 50% of the time. This means going out to the generator and pushing the OFF button, then 3-4 hours later, pushing the AUTO button.The generator will shut off for no apparenht reason. will start up immediately. usually runs about 30 seconds then dies. thought the genera ... 2002 seabreeze 34' generac 5500w starts and runs fine. Then, cuts off after 5 to 10 minutes. Won't restart for at least 30 minutes or, until the generator returns to 'cold' condition. ...

What causes a Generator Run then Shut off? Some of the reasons your generator won’t stay running include the following: 1. Overload. The safest way to start …Generac Generator Tech Talk Generac Air Cooled Generators; ... Does it sound like it fires up just briefly then shuts down? Could be brushes if it is a 2010 or newer unit. ... Currently own the Generac Guardian 17 kW model running off NG. Unit has run the self test with no problems for last 16 months. Last week it would start, run for about 2 ...Generac, Guardian, Honeywell, Siemens, Centurion, Watchdog, Bryant, & Carrier Air Cooled Home Standby generator troubleshooting and repair questions. ... Pressing the button once will start shutting the generator off but it immediately goes back to Auto mode. The same goes for holding the button, it will remain off for as long as I hold the ...Get in touch with our support team. The generator automatically detects when the utility power is lost to the home and then begins its startup process. Once the generator is running, power is restored to the home. When utility power is restored, the generator automatically shuts itself off.The most popular reason behind this issue is the overloading of the generator. Water Levels: After a few seconds, water levels in the radiator may also cause the system to turn off. Place it in a radiator filled with water. Allow it a routine after a month to check the water level in the radiator.

Iron chef pickerington menu.

Honda generator eu6500is starts and runs for a few seconds then shuts down, like power off. Would not start initially only on carb cleaner cleaned carb throughly and checked oil pressure sensor by inpluggjng and the same result. It's like brand new last ran 2 yes ago what else would cause the shut down.First, make sure the spark plug is in good condition. Next, check the continuity using an ohmmeter. Replace it if you find a break in the continuity. 5. Low Engine Oil Level in the Generac Generator. When the engine oil level is too low, the Generac will shut down to protect the engine from damage.Generac, Guardian, Honeywell, Siemens, Centurion, Watchdog, Bryant, & Carrier Air Cooled Home Standby generator troubleshooting and repair questions ... and that I don't want the generator running (potentially for days) without my ability to power it down every 24 hours and check the oil, etc I plan to switch it from AUTO mode to OFF mode ...If it is three flashes, tap stop once more to get two digit fault code. Code 2 is oil pressure, 1 is temperature. 24 is a bad temp sensor. 36 usually indicates fuel. I would suspect the temp sensor or a loose or broken fan belt. We have an Onan Quiet Diesel 10000 (10HDKCA) that will run for a while and then shut off.Standby generators often come with an automatic shutdown system. When the main power supply is restored, these generators automatically switch off, ensuring a smooth transition. Graph 1: Frequency of Automatic Shutdown in Various Generators. This graph illustrates how common automatic shutdown systems are in different types of generators.RPM Sense Loss, Code 1501/1505/1511/1515 -. If the unit was running and shuts down, attempting to restart, clear the alarm by pressing the ENTER button twice, then press AUTO. Next, remove some of the loads. Try putting it back in AUTO and then restart. If it does not start after doing this, you will need to place a service call.

Check the oil level. Most generators have a dipstick like the one in your car. Pull it out, wipe it off with a rag, then pop it back in. After about 30 seconds, take it out and check whether the oil is above the “empty” mark. If not, go ahead and refill it. Like gasoline, oil can go bad over time.6. Start the set and let it run. While it is running, measure the output voltage of the set. With these wires disconnected, then engine should run for longer than 5 minutes. Wile carefully monitoring for engine overheating, or any strange noises (shut it off immediately if either are noted), let the engine run for about 10-15 minutes. 7.Nov 12, 2017 ... Troubleshooting a Generac 20KW Generator & Installing Engine Block Heater. I had never previously worked on one. This one was sitting with ...This wire is grounded when a generator automatically starts after a power loss. The 194 wire provides 12 VDC to the ATS and is always powered. 2. Confirm that the generator's Main Line Circuit Breaker (MLCB) is in the ON position. If this is in the OFF position when the generator is in AUTO mode, then the generator will start, but the … The generator may shut off if it is under too much load if the fuel shut-off valve is engaged, or if the oil level is low. This is a microprocessor controlled genset, and will store a fault code when it shuts down. Let's see what code is set. Go to the genset and use the switch on the set itself. Press 'Stop' 3 times within 5 seconds. The light in the switch will start flashing. If the light flashes 3 times, pauses for 3 seconds, and flashes 3 more times, press and ...The most popular reason behind this issue is the overloading of the generator. Water Levels: After a few seconds, water levels in the radiator may also cause the system to turn off. Place it in a radiator filled with water. Allow it a routine after a month to check the water level in the radiator.Most generators will run on fuel such as diesel or gas. As such, if there’s a problem that keeps the fuel from reaching the engine, then your Honda, Generac, or Briggs and Stratton generator will keep shutting off. These problems will either be in the fuel tank or the fuel pipes.Generac Generators (SEARS, etc.) . 5500 Watt Generac shuts off. Thread starter Swamp239 ... Now, it will only run for 5 to 10 secs, then shuts off immediately, regardless of load. I know a little about small motors, but dont really know much of aanything about generators. I have a volt meter, can someone recommend …Jul 2, 2005 · Generac starts then shuts off. Mission Statement: Supporting thoughtful exchange of knowledge, values and experience among RV enthusiasts. My Generac starts OK but runs for about 1 Min then shuts off. Try to start again and use the prime but fuel pump keeps running and it will not start. Let it set for awhile and it will start but shuts off again. Below are the potential causes of the generator producing high voltage output with DIY fixes. 1. Unstable/Extremely High RPM/Engine Speed: The engine's Speed/RPM directly impacts the generator's output voltage; if it's unstable the generator will not provide the desired voltage, Also if the RPM is too high you will have to face overvoltage.

First, make sure the spark plug is in good condition. Next, check the continuity using an ohmmeter. Replace it if you find a break in the continuity. 5. Low Engine Oil Level in the Generac Generator. When the engine oil level is too low, the Generac will shut down to protect the engine from damage.

New spark plug, carburetor, new gas after putting on new carburetor it ran for a little longer then usual me 15 minutes then tried turning back on and … read more. Eric Noe. Technician. 3 satisfied customers. Generac generators support. I just purchased a 6500-watt. generac generators support.Dirty carburetor. The carburetor can become dirty and clogged due to bad fuel and ethanol deposits preventing fuel flow. Clean the components making up the carburetor. Replace if needed. Low engine oil level. A sensor on a Generac generator protects the engine by not allowing it to run when the engine oil level is low.Step 2: Wait for 30 seconds. Step 3: Put the generator into the “MANUAL” position on the controller. The generator will either start or will make three attempts at starting. If it starts, let it run for 5 minutes, and then put the generator back into the “OFF” position. Step 4: Wait for another 30 seconds until it has completely shut down.earlier this year, there was gas that was like 3 months old, non stabilized...earlier this year it did not start, i pulled the carb, cleaned it up, dumped the old gas, put fresh gas that has been stabilized in it. generator ran last month for a test of about 30mins. ran today a total of 4hours on/off 2hours running full out, and 2 hours with stalling and restarting.If you want more information about the installation process, sizing a generator, or what backup power solution is right for you, we're here to help! You can give us a call at: (727) 938-8473. (813) 814-5900. (941) 505-1212. Or contact us online or via email ( [email protected] ) so we can help you understand your options and next steps.If it is showing the over speed fault on the computer every time is shuts down then there are other problems such as the computer has lost RPM communication with the from the speed sensor, I had this once that was caused by field mice that got into the generator and chewed up some wires, I repaired the damaged wires and put moth …Try unplugging loads and running the generator with less applied. Is the fuel shut-off valve turned on? Without the fuel valve turned completely on, gas cannot get to the engine for proper function. If the fuel valve is on, check the fuel filter and fuel line for clogs. Clogged fuel lines may be restricting the amount of fuel getting to the engine.I shut off the generator breaker and removed the 15 amp fuse from the control panel. Then I gained access to the control panel and unplugged J2 (which goes back to the governor) from the control board. I also unplugged the connector (two blue wire) above the unit on the wall that goes to the controller assembly.Lp generac generator cranks up, runs a minute and shuts off, generac 15 kw approx, 2004, yes, I am a master electrician, - Answered by a verified Technician ... it runs approx 15 seconds, then shuts down and reads "under voltage". What is the cause of this? We bought it 7/29/10. ... 04390-1 15 KW LP Generac Guardian Air-cooled house generator ...If so, verify proper installation. Ensure fuel is turned on. A shutoff valve should be within 6ft of the unit. Verify fuel lines have been bled. Air pockets in the line will prevent the unit from starting, this is especially common if LP was recently refilled. Check for an empty or low LP tank. Verify proper fuel conversion if running on LP.

Grey sunz tattoo.

Giovanni's pizza menu lucasville ohio.

4. Use Fresh Fuel. One of the common causes your Generac generator won’t start because the gasoline is old. Gasoline tends to degrade over time. If the fuel looks cloudy or looks like there’s been some separation, you should consider replacing it with fresh fuel. Siphon the gas and fill the tank with fresh gas.Generac Generator Troubleshooting, Help, and Repair Forum | Gentek Power ... The fault engages shut down mode, which is cleared by turning unit to manual mode, and then to history, and the fault clears after returning to manual mode. ... In the 'Edit' menu, find 'Exercise Time' and set the Quiet Test feature to Off. This will make the …Generac 17500 with 140hrs on it. Starts every time but now screaming way above normal high load rpm's. Then shuts off. What chef with spark plug out and it doesn't just die it's shutting off.At the controller, set the generator to OFF. Remove the 7.5A fuse from the controller. To turn the generator back ON: Install 7.5A fuse in controller. Confirm the generator MLCB (generator disconnect) is OFF (OPEN). At the controller, set the generator to AUTO mode. Generator will start and run. Allow generator to run and warm up for a few ...03 - Craftsman Generator Fuel Cap. As fuel is consumed by the engine, the level in the fuel tank lowers. To make up for this, the fuel cap uses a small vent to allow air to enter the tank. If the fuel cap vent is clogged, air won't be able to enter the tank and a vacuum or "vapor lock" will occur. This stops the flow of fuel to the ...As far as the generator goes, it should have a on-auto-off switch on it. Turn it to off, and then it won't kick on. On the matter of a breaker not turning off the power to that circuit, that sounds wrong to me, and I would have them back out to correct that, as that is not a correct installation.When this happens, it will cause your generator to stall out and shut down because there isn’t enough fuel in the engine. However, if the choke is turned on, it cuts off airflow and sends a higher supply of fuel into the engine, which is why your generator only runs when the choke is on. 5. Clogged Fuel Filter or Fuel Line.Item/model #0043903 Serial# 4149043 OHVI 1.0 15k propane Generac I use my Generator as a backup for my solar system. I purchased it back in 2006. ….

3. If a Wi-Fi extender or Booster is in use, verify that the device is not shutting off or falling asleep from non-use, as some boosters may power down if data consumption is too low. Mesh network setups can sometimes experience issues due to the generator bouncing back and forth between mesh network access points. 4.Originally Posted by georgebonord. Hi Everyone. We live in the South where it gets hot in the summer. The heat causes us to run the gasoline Onan 5500 generator to power the A/C. We have a 2003 HR Vacationer on a W22 Workhorse chassis. The generator will shut down after 2-3 hours of run time. It will restart but only for a few seconds.Generac 22kW, running on Natural gas. Unit is approximately 2 months old. Unit starts and runs well. After running a while, it starts to shut off, then immediately kicks back on. For lack of an explanation, it acts like I turn a key off, and just as it starts to stop running, it immediately kicks back on. It seems to do that after running solid ...Damaged pole of a multiple rotor or stator may be the other reason of low frequency; Decrease or increase in the supply power system may be a reason for this problem'. Nozzle assembly failure, fuel filter failure, fuel pump failure, excessive unit vibration or a heavy load, etc. are also the key reasons for low frequency.Provides clean, stable power ideal for sensitive electronics, tools and appliances. Compact and Lightweight. Makes transportation easy with built-in handle. Economy Mode. Automatically adjusts engine speeds to save fuel and reduce sound emissions. Integrated Off/Run/Choke Knob. Simplifies startup procedures.Have a Briggs and Stratton home generator. Engine starts, runs for 10 15 seconds, shuts down, starts again...runs 10-15 seconds shuts down....does this about 4 or 5 times and then throws F4 fault code: Engine failing to start. It's odd because the engine starts and actually runs for a while.I purchased this generator the end of December so its only about 3 months old. Use it daily and it was running fine and then shut off. Tried restarting it after checking oil level and fuel levels. It starts but will not stay running...runs for about 10 seconds and shuts off. I have replaced spark plug, fuel filters air filter and carburator.I have a generac guardian ultra source M# XXXXX 15,000 it would start and run for 10 minutes then shut down I let it sit around for a few months and then took it to a repair center they said it needed … read moreOHVI 1.0 15k propane Generac I use my Generator as a backup for my solar system. I purchased it back in 2006. Other then the 30 day exercise period It only runs when battery power is low, which is rare since my system has solar and wind systems to supply daily battery charging. ... Off Topic; ↳ Introduction; ↳ General Discussion; Generac generator runs then shuts off, Step 2: Wait for 30 seconds. Step 3: Put the generator into the "MANUAL" position on the controller. The generator will either start or will make three attempts at starting. If it starts, let it run for 5 minutes, and then put the generator back into the "OFF" position. Step 4: Wait for another 30 seconds until it has completely shut down., 1998 Rexair motor home with a Generac Model #GN480 Q55G serial#301011. Starts easy, runs great for about 1 to 2 minuets, then shuts off. Not low on oil. Generator will run as long as I have 12 volts a … read more , If you fail to turn off the main breaker, you risk damaging the items that are running on power from the generator with a power surge once the power grid is back up. Running a generator when the main breaker is on can even cause a fire once power is restored. You can switch off your main breaker manually, or by the use of a transfer switch., Generac generators support. I have a 10 KW generac standby generator runs for 10 to 20 seconds and then shuts off on LP - Answered by a verified Technician ... Generac generators support. I have a 10 KW generac standby generator runs for 10 to 20 seconds and then shuts off on LP does not start when I switch it to natural gas., Solution: Check your oil levels; keeping the optimal oil levels can solve this problem and help your generator’s smooth functioning. Here’re the best generator engine oils on the market to buy, do check them out. 3. Water Levels – Water levels in the radiator can also cause the system to switch off after a few seconds., The generator may have shut down because of overload, which can damage its internal components. In this situation, you need to reset the circuit breakers and power fewer appliances with it. If the problem is not resolved, then there may be something wrong with the generator itself. You should have a Generac Service Dealer inspect it …, What causes a Generator Run then Shut off? Some of the reasons your generator won’t stay running include the following: 1. Overload. The safest way to start and use a generator for power generation or other task is to start it, let the roar become smooth then connect the load., Generator Keeps Shutting Off. If your generator keeps shutting off, there could be a number of potential causes. Here are a few things you can check. 1. Overloading. If you're running too many appliances or tools that require more power than the generator can provide, it can cause the generator to shut off., Check the oil level. Most generators have a dipstick like the one in your car. Pull it out, wipe it off with a rag, then pop it back in. After about 30 seconds, take it out and check whether the oil is above the "empty" mark. If not, go ahead and refill it. Like gasoline, oil can go bad over time., 1. The generator still starts when put into the auto mode. And when it starts the transfer switch immediately switches from the Utility position to the generator position. 2. When the generator is shut off the transfer switch will not return to utility power., The generator will shut off for no apparenht reason. will start up immediately. usually runs about 30 seconds then dies. thought the genera ... 2002 seabreeze 34' generac 5500w starts and runs fine. Then, cuts off after 5 to 10 minutes. Won't restart for at least 30 minutes or, until the generator returns to 'cold' condition. ..., Costco sells several brands of generators, including Cummings, Generac, Honeywell and Champion. Their online selection is sometimes more extensive than what is available in the sto..., Nov 8, 2020 · I have a Generac 15k NG unit, model 0053820, serial# 4652524, 188 hours.It but was last run nearly a year ago. It starts and runs briefly (maybe 5-10 seconds) then shuts off with a flashing overspeed light. , Turn off the generator and let it cool down. Put on gloves and safety goggles. Open up the generator's cover or panel to get to the carburetor. Spray carb cleaner on all the carb parts. Wait for it to loosen the grime, which usually takes 10 to 15 minutes. Use a brush to scrub away the loosened dirt gently., Need help - generator runs for 5 to 10 minutes then dies Generac Portable Gasoline Generators. Reply. Junior Member 6 posts. norm200 Jun 30, 2015. I have a 2005 Guardian gas generator model 004582 15,000 watts.i cleaned the carb,but it only run for 5 to 10 minuets then die's,it cranks back up does same thing. the generator run's at a high also ..., As a general rule, a generator will stall for any of the following seven reasons: bad fuel, clogged jets in the carburetor, a dirty air filter, faulty spark plug, a compromised bond between the float needle and seat in the carburetor, a faulty low oil indicator shut off, or a stuck choke butterfly valve. Reason for Generator Stalling. How to Fix., See full list on pickgenerators.com , My Generac 4000 EXL starts well but then only runs for 5-10 seconds and then stops. It seems like it is starved for fuel. It will start right up again and do the same thing. I can do this over and ove … read more, I have a generac generator (np 52g) Model 9205, it starts easy runs 45secs to 1 minute then shuts down, usually making a short bubbling before. It appears to be the fuel pump but I cant find one using the model number plate on the side of the engine!!! Mechanic's Assistant: Do you have fuel in the tank? If so, is the shut-off valve open and the ..., I will start and run good for about 30 seconds then it shuts down everything. Oil level is ok , when it shuts down I hear the fuel solenoid click at the same time. ... I have a Generac Generator model 04456-2 with a small issue. I am unable to reset the exercise timer. ... It starts at a time other than when it is set for. when it shuts off the ..., Generac 22kW, running on Natural gas. Unit is approximately 2 months old. Unit starts and runs well. After running a while, it starts to shut off, then immediately kicks back on. For lack of an explanation, it acts like I turn a key off, and just as it starts to stop running, it immediately kicks back on. It seems to do that after running solid ..., Gas line will be changed to 3/4 " in to gen, with the Generac vibration line then a 36" x 3/4 pipe to 2nd stage regulator. When gen runs for 10 seconds the flow of gas is 10.5" w.c and the RPM is steady, If you fail to turn off the main breaker, you risk damaging the items that are running on power from the generator with a power surge once the power grid is back up. Running a generator when the main breaker is on can even cause a fire once power is restored. You can switch off your main breaker manually, or by the use of a transfer switch., Shutting the Generator Off. It is very important to remove the load (devices and equipment pulling power from the generator) prior to shutting it down. 1. Set the main utility disconnect to OFF (OPEN). 2. Set the generator MLCB (generator disconnect) to OFF (OPEN). 3. Allow the generator to run for a cool-down period of approximately one minute., The installer did not activate it and left, so I activated it myself using Generac's instructions. But when I turn it into the Auto mode it starts counting down 5 seconds, starts and just keeps running. I let it run for about 2 minutes and manually turned it off because it would not turn off by itself., Item/model #0043903 Serial# 4149043 OHVI 1.0 15k propane Generac I use my Generator as a backup for my solar system. I purchased it back in 2006., Makes no difference. I think the manual says that the generator should run 10 seconds before it shuts down on low oil pressure. Never runs more than about 3 seconds. Fresh fuel, but has sat for a year without running. Less than 6 total hours run time on the generator. Stored inside. I start it choked, it revs up high then dies., A: Check the level gauge on your propane tank regularly. If the tank is emptying much faster than expected based on your generator's fuel consumption, there may be a leak or other issue. The generator will shut off immediately once the tank runs dry. Q: I just filled my propane tank, but the generator still shuts off after running for a while., I have a troybilt generator 6000 watts model 030475. This weekend it started shutting off after 5 minutes or so run time. It starts backup easily runs fine then shuts down again. Fuel is fresh. Any id … read more, Most generators will run on fuel such as diesel or gas. As such, if there’s a problem that keeps the fuel from reaching the engine, then your Honda, Generac, or Briggs and Stratton generator will keep …, A generator can backfire when it's shut off due to a buildup of unburned fuel in the engine. It is the residual motion of the piston that ignites the spontaneously combusting air-fuel mixture in the combustion chamber. When the generator is running, the air-fuel mixture is ignited in the combustion chamber, producing energy to power the ..., When this happens, it will cause your generator to stall out and shut down because there isn’t enough fuel in the engine. However, if the choke is turned on, it cuts off airflow and sends a higher supply of fuel into the engine, which is why your generator only runs when the choke is on. 5. Clogged Fuel Filter or Fuel Line., Have Enough Fuel Available. Even if your generator is ready to run, you'll need enough fuel to keep it going in the event of a prolonged outage. Keep at least 10 gallons of fresh gasoline for ...