Low subcool high superheat

A unit that is overcharged will have a low superheat temperature and a high subcooling temperature. With low superheat, there is a risk of the refrigerant passing through the evaporator too quickly with liquid refrigerant finding its way back to the compressor. This can cause the compressor to fail. High subcooling will also damage the compressor.

Low subcool high superheat. What causes low superheat and high subcooling? Because these readings are normal, the low suction pressure is caused by insufficient heat getting to the evaporator rather than low refrigerant. CAUSE #2: A faulty, plugged-in, or undersized metering device is to blame. As refrigerant is added to TXV systems with high superheat, double-check the ...

the superheat constant. Subcooling involves two measurements as well: one for pressure and one for temperature, but this one is taken from the liquid line. Target subcooling can be found on the system nameplate. The actual subcooling should be within ±3°F of the target subcooling for correct refrigerant charge. An improper superheat value can

The higher the efficiency of a system, the more critical it is that it is charged properly. The Fieldpiece Superheat and Subcooling for Air Conditioning and Refrigeration meter, model SSX34, measures suction line, or low side, line temperature and pressure. It then calculates actual superheat in real time using built in P/T charts.When an evaporator float switch is used in the drain pan of an air conditioner or heat pump, if the drain pan fills up the float will interrupt the low voltage circuit to. the compressor contactor. A system operating with a high superheat and a high subcooling most likely has. A refrigerant restriction.The system will have symptoms of low suction pressures, high evaporator and compressor superheats, normal-to-high condenser subcooling, low compressor amp draws, and low head pressures. ... Evaporator superheat: 40°F: Compressor superheat: ... All of the liquid in the condenser will probably sit there for a while and subcool because …How to Calculate Superheat. 1. Obtain suction line temperature: First, measure the temperature of the suction line near the evaporator outlet using a digital thermometer or a clamp-on thermocouple. 2. Determine saturation temperature: Next, read the low side pressure gauge on your HVAC gauges while equipped with corresponding refrigerant scale ...Oversized Air Conditioner (Leading To Short Cycling) 3. Low Airflow Over Condenser Coils (Dirty Coil) 4. High Refrigerant Charge (Remove Freon) 5. Metering Device Feeding Too Much Refrigerant Into Evaporator Coil. 6. Wrong Superheat Measurement.The main reasons your compressor will have simultaneously low head pressure and high suction pressure is due to: Bad or leaky compressor valves. Worn compressor piston rings. Leaky oil separator return line. Your compressor valves may become inefficient due to poor sealing from dirt and debris deposits.

If it does it in decent weather: It's airflow. Or, more accurately a lack of heat load on the evap. Your txv has bogged all the way down, creating a high subcool. It's bogged so far down, and still can't maintain a decent superheat. This is from your low evap temp, low sh and high subcool.When it comes to purchasing a vehicle, finding an affordable option is often at the top of many buyers’ lists. Two popular choices for budget-conscious individuals are low-cost car...High Suction - Low Superheat and No Subcooling 2.5 ton lennox condenser 3 ton drive on blower 3.5 ton evap 50 evap 45 SLT 100 condensing temp 105 LLT ... Elevated suction, low superheat, lowish head and low subcooling are typically symptoms of an overfeeding metering device. But 10 SC and 7 SH are reasonable numbers though 7 SH is probably ...A high superheat, a warm suction line, and 0 degrees subcooling in an A/C system likely indicate a low refrigerant charge. These symptoms show inefficient heat absorption in the evaporator and inadequate refrigerant to condense in the condenser. Therefore the correct answer is: A) Explanation:Check into superheat when the house is extremely warm will give you an inaccurate reading but your temperature drop should be 15 to 20 degrees. The more humid it is outside in the summer the lower your temperature drops going to be puts more load on the AC. I do a triple evac with nitro to remove non condensables.ค่ามาตรฐาน Superheat กับ Sub-cooling ของสารทำความเย็น R22 มีค่าเท่าไหร่ครับ ... - อุณหภูมิของท่อน้ำยา ด้าน Low และด้าน High - แรงดันของน้ำยา ด้าน Low ...Low-volume stocks trade between 10,000 and 100,000 shares a day. Some may have no trades at all on certain days. The biggest risk of trading low-volume stocks is limited liquidity....

By keeping an eye on both subcooling and superheating, you can optimize your refrigeration system’s efficiency, prolong its life, and minimize energy consumption. Navigating through this hub page, you have learned the importance of maintaining the ideal superheat range, as both high and low superheat can cause potential problems in your system. Jess Gordon is the service manager at Tempo Mechanical Services, Irving, TX. The company was Contracting Business magazine's 2003 Residential Contractor of the Year. Jess can be reached at 972-579-2000, or by e-mail at [email protected]. Superheat is a way to ensure that the system is boiling off all of the liquid before it exits the evaporator.Step-by-Step Low Superheat High Subcooling Fixes. Once you’ve identified low superheat high subcooling imbalances in your refrigeration system using the diagnostic tools and equipment mentioned earlier, it’s time to take corrective action. Here’s a step-by-step process to help you address these issues effectively: 1. Ensure Safety … If superheat is low and sub-cooling is high: Charge must be adjusted. System overcharged If superheat is high and sub-cooling is high: Could have blockage in coil, orifice or line set. If superheat is low and sub-cooling is low: Orifice could be too big, there is no orifice in the unit of the orifice is stuck and refrigerant is by-passing it.

Cox internet outage macon ga.

So after letting it run another hour (steady state) the high pressure came down and the low pressure came up. (270/80). That puts me in a low subcool/high superheat scenario.... which probably means undercharged (if I understand all this correctly ). Probably a classic goodman coil leak somewhere...The system will have symptoms of low suction pressures, high evaporator and compressor superheats, normal-to-high condenser subcooling, low compressor amp draws, and low head pressures. Here is a service checklist for a restricted liquid line after the receiver and before the filter drier: ... Compressor superheat: 70°F:How to measure SUPERHEAT and SUBCOOLING! HVAC/R Training Video.How to calculate SUPERHEAT and SUBCOOLING on your air conditioner or refrigerator? R22 R410a R...High superheat, low subcooling—or high subcooling, low superheat—can tell us a story about the system and its needs. Ensuring that a system is fully operational within the appropriate ranges means that you need the right tools …

Bryan with HVAC School goes over AC pressures, subcooling, and superheat in his troubleshooting mindset presentation from the BTrained HVAC training event in Birmingham, AL. Bryan also talks a bit about his educational photo-sharing app, MechPic. The suction pressure and suction saturation give us an idea of the refrigerant’s boiling temperature.Superheat and Sub-Cooling. Whenever an HVAC technician needs to add refrigerant to a system or adjust the charge the tech needs to know what superheat and/or sub-cooling is to properly ensure the refrigerant charge is correct. It is also important to have a pressure-temperature or PT Chart to properly read the pressures and temperatures.The symptoms are low suction, normal subcooling, and high superheat when a TXV fails “shut,” but there are some other issues to watch for that can actually result in overfeeding the coil. Schrader in the Port. The external equalizer tube on a TXV connects to the suction line at the evaporator outlet and provides a closing force to the valve.I agree, charge with suction superheat on straight cool [only] and then verify the subcooling with a clean-as-new condenser coil. The subcooling changes as the coil ages too. Verify with checking Discharge superheat [apx 100 degrees]. Charging with subcooling only works to get the highest efficiency on High SEER matched system.Has been checked numerous times. 1 thing that stands out is..the superheat is always normal but subcooling is always real low, usually 2 or 3 degree subcooling. ... Some units operate with a very low subcooling, such as window units & some self contained units. Also saw where, some new high efficiency equipment runs as low as 4-F subcooling.Low condenser subcooling can mean a low charge, while high condenser subcooling can mean an overcharge — but not always. For example, this is not true for capillary tube systems having no receiver; a capillary tube system can run high subcooling simply from a restriction in the capillary tube or liquid line. ... High compressor superheat; Low ...In my thread asking how high charge level causes high subcooling, you told me that low charge level causes low superheat because the refrigerant gets subcooled less in the condenser which makes the refrigerant enter the evaporator at a warmer temperature, which leads to more superheat. ... High superheat with low condenser sub-cooling generally ...These are my readings 296psi high side, 95.8 lstat, 93.6 line temp, 2.3 subcool. 140.6psi low side, 50.1 vstat, 51.3 line temp, 1.2 superheat. 20degree delta tee across the return and supply. I may have missed something somewhere, but all that looks like an overfeeding TXV. 50˚ saturated suction pretty much eliminates low airflow, particularly ...High superheat= not enough refrigerant in the evaporator. Low subcool= not enough refrigerant in the condenser Compression ratio is fine, unlikely to be the valves. It isn’t possible for you to have liquid refrigerant in the liquid line if the line is hotter than the boiling point of the refrigerant. A Negative subcool number is not a thing.I had posted in a previous thread about the superheat reading taken on my system being about 11 *F too low (possible overcharge). Today another tech came out and measured everything again. This tech measured the subcooling as well this time. Here are the measurements he took: OAT DB: 68 *F Low side: 68 psi (39 *F) High side: 140 psi …Originally Posted by Brad gall. .12 degree subcooling and 0 on the superheat both measured at the condenser.. This just don't make sense to me, you would think with only a 12° SC if you were able to get that with a wide open valve, that there would be some flashing, and not have a 0 SH, heck you got me.Also, the TXV's job is to maintain 8 to 15 degrees superheated, so having low superheat and high subcoooling could be an overcharge. Check the amperage on the compressor and see where it's at. ... 4 degrees of superheat with 22 degrees of subcool almost looks like an overcharge, but your pressures aren't adding up right. ...

Subcooling degrees are figured by taking the difference between the discharge saturation temperature and the discharge line temperature. The amount of subcooling for optimum operation should be specified by the equipment manufacturer. An overcharged system will have low superheat, potentially allowing liquid refrigerant to damage the compressor.

Apr 8, 2020 · Subcooling is a measurement of temperature DECREASE of a liquid below its saturation (mixed liquid/vapor) temperature at a given pressure. For example, water boils at 212° Fahrenheit at sea level (atmospheric pressure of 14.7 PSIA). If water is 212°F and at atmospheric pressure at sea level, you can be sure it is at saturation, which means it ... Bryan with HVAC School goes over AC pressures, subcooling, and superheat in his troubleshooting mindset presentation from the BTrained HVAC training event in...May 15, 2021 · 3. Airflow through the evaporator is too high. When there is an excess flow of air through the evaporator coil, the capability of the system to remove moisture is reduced. The vapor picks up more than usual heat which causes the suction pressure to be higher than normal pressure and has a higher superheat. 4. At approximately 85 degrees Fahrenheit (29.4°C), the pressure for R-410A could be around 230-260 psi on the low side and 500-550 psi on the high side, but actual values can vary. What happens if superheat is too high? Excessive superheat can lead to reduced cooling capacity, insufficient cooling, and potential compressor issues.Ok so my question is this, I just recently moved to another company, they tell me to do sh and sc by just hooking gauges and add or subtract line temp from what gauges reading. And use 10 degree for sc and 20 for sh. shouldnt I be taking indoor wet bulb and outdoor dry bulb.Replace air filters and the blower wheel. Overfeeding of the metering device. Ensure sensing valve of the TXV is properly insulated. Insufficient heat load to the coil. Clean the filters and the coil. Oversized AC system. Consider going for a well Sized AC unit. Read also: How to Fix High Superheat Low Subcooling.Common Causes of High or Low Superheat. Superheat is a crucial factor in refrigeration systems that controls the temperature and pressure of refrigerants. It measures the amount of heat added to vapor from its boiling point at a particular pressure, indicating how well the evaporator coil transfers heat between refrigerant and air.Superheat and Sub-Cooling. Whenever an HVAC technician needs to add refrigerant to a system or adjust the charge the tech needs to know what superheat and/or sub-cooling is to properly ensure the refrigerant charge is correct. It is also important to have a pressure-temperature or PT Chart to properly read the pressures and temperatures.Sorry I typed in the wrong temperature of the evaporator and condenser temperature and the superheat and subcool. Temp outside was near 100F probably 98F, inside was 79F. High side: P = 304.6 psig . T = 94.9 F . T co = 154.8 F .

Michelle meredith wesh.

Reset wyze cam v3.

The Low Suction Superheat Diagnostic is annunciated when the measured suction superheat stay below 3.96F for 1 continuous minute. If it bounces up and down at the threshold, the 1 minute timer resets. Suction Superheat Description. Superheat is the difference between suction temperature and saturated suction temperature.the superheat constant. Subcooling involves two measurements as well: one for pressure and one for temperature, but this one is taken from the liquid line. Target subcooling can be found on the system nameplate. The actual subcooling should be within ±3°F of the target subcooling for correct refrigerant charge. An improper …A 30-psi pressure difference is usually the minimum across TXVs. This reduced refrigerant flow causes a starved evaporator that will in turn cause low suction pressures and high superheats. However, this may be offset by increased subcooling at low ambients.Low condenser subcooling can mean a low charge, while high condenser subcooling can mean an overcharge — but not always. For example, this is not true for capillary tube systems having no receiver; a capillary tube system can run high subcooling simply from a restriction in the capillary tube or liquid line. ... High compressor superheat; Low ...In extreme cases, insufficient subcooling can even cause the refrigerant to return to a gaseous form before reaching the evaporator piping. The most common cause of insufficient subcooling is low refrigerant charge. However, too much subcooling can damage your system. An excessive amount of coolant will raise subcooling to a problematic level.From the Goodman manual for that model. Outside drybulb 95F inside drybulb 80F. Hi pressure = 335 Psig, Lo pressure 130 Psig. Which is 20-30 psi off on both. But I was under the assumption if it where low on 410a there would be high superheat and high subcooling. Like I said I'm new. With the excessive subcooling and no superheat, I am confused.That means understanding and measuring all three types of superheat: evaporator, total, and duct system. 1. Evaporator superheat. To measure evaporator (indoor coil) superheat, first measure the suction line temperature at the evaporator outlet. Next, measure the refrigerant pressure at the suction line of the indoor coil.Hey guys, could use some help. Had a Carrier unit with 410a, not sure of the metering device. Cooler weather, 63 outside, maybe 70 in the house, so obviously not a lot of load. I'd been seeing 20ish degrees of superheat all day on other calls. On this unit Suction was about 105\32, head was bouncing between 200 and 220. Subcool was bouncing between 10 and 15.A low suction superheat does not 'indicate' an overcharge. Low suction superheat is the result of too much refrigerant in the evaporator for the heating loading of the evaporator at that moment in time. Post the startup report data: Outdoor Ambient temperature. Condenser air temp in. Condenser air temp out.Good Subcooling Value for R-410A: Similar to superheat, the ideal subcooling value for R-410A can vary depending on factors like system design and operating conditions. However, a common target for R-410A systems is to achieve a subcooling value in the range of 8 to 15 degrees Fahrenheit (°F) or approximately 4.4 to 8.3 degrees Celsius (°C).Low capacity, a starved evaporator, high superheat, and low suction pressure are all symptoms of a(n) _____. ... high subcooling and high compression ratios are all symptoms of a(n) _____. refrigerant overcharge. All reciprocating compressors should immediately go into a vacuum if the suction line is valved off when the compressor is running ... ….

High superheat due to excessive heat load and low subcooling due to poor compression. In practice, more than 95% of issues, when we see high superheat and low subcooling, …In this HVAC Video, I Show SEVERELY UNDERCHARGED, UNDERCHARGED, CORRECTLY CHARGED, and OVERCHARGED Scenarios on a Running R-410A Refrigerant Air Conditioner ...Low subcooling means you won't have enough liquid refrigerant to feed your expansion valve. High subcooling means you may have to much refrigerant in the system or you have a subcooling circuit in the system that helps subcool the liquid refrigerant more. I've seen subcooling circuits on chillers and VRF/VRV systems.Evaporator Superheat Method: 1. Take the suction line pressure and temperature at the condenser's suction service valve (air conditioning) or service port at the compressor (heat pump). If you use a probe-type thermometer, put a piece of pipe insulation around the probe and pipe. 2.High superheat and low subcooling. What method is used to correctly charge a TXV system? Subcooling method. Which is a fixed orifice metering device? AXV, Piston, TXV ...Freezer superheat and subcooling. Hello HVAC tech I am working on a walk in freezer box temp is -10 degrees. this is a R402A refrigerant unit by Larkin it is a Copeland compressor. My suction temp. at the compressor is 33.7 the saturated temp is -32 at 10 psi. the High side is 215 psi saturated temp 89 degrees and the pipe temp is 91 degrees ...Step-by-Step Low Superheat High Subcooling Fixes. Once you've identified low superheat high subcooling imbalances in your refrigeration system using the diagnostic tools and equipment mentioned earlier, it's time to take corrective action. Here's a step-by-step process to help you address these issues effectively: 1. Ensure Safety PrecautionsQuickly calculate Superheat, and Subcooling measurements for R22 & R410A refrigerants. R410A R22 Outdoor Temp . Indoor Temp . Suction PSI *Required. Liquid Line ...In this HVAC Video, I Show SEVERELY UNDERCHARGED, UNDERCHARGED, CORRECTLY CHARGED, and OVERCHARGED Scenarios on a Running R-410A Refrigerant Air Conditioner ... Low subcool high superheat, The saturation temperature on the low side was 28 degrees. I had a subcool of 20 and a superheat of 22. The delta T was 24F. The filter opening was 16X25 inches. The condenser coil look like it could use a cleaning. The fan amperage was 6.8., Take the condensing temperature and the condenser outlet temperature, and the difference between the two is the amount of subcooling. “Let’s say the condensing temperature is 100°F. Put a thermistor on the condenser outlet, and let’s say that’s 90°,” continued Tomczyk. “So, you have 10° of subcooling. Technicians get confused ..., If I have my theroy right I have a low superheat of 10 and a high subcooling of 21. Ambiant temp outside is 81 and all temps are in F. 19-07-2011, 03:16 AM #40. , A good superheat and subcooling value depends on the specific system, but typically, superheat can range from 5 to 20 degrees Fahrenheit (2.8 to 11.1°C), and subcooling can range from 10 to 20 degrees Fahrenheit (5.6 to 11.1°C). ... Signs of a faulty TXV can include improper cooling, erratic system behavior, high or low superheat, or frost ..., May 6, 2015 ... Comments28 · Explaining Superheat and Subcooling to Your Apprentice! · Class - What Superheat Signifies · Super Heat : Total System Superheat &..., Troubleshooting Using Superheat and Subcooling Data. Low superheat: Indicates too much refrigerant in the evaporator, likely due to overcharging. High superheat: Suggests too little refrigerant in the evaporator, which may be caused by low refrigerant levels, insufficient heat reaching the evaporator, or a dirty/defective metering device., High evaporator superheat; High compressor superheat; Low condenser subcooling; Low compressor amps; and; Low condensing temperatures and pressures. Also, remember that it is the British thermal units (Btu) that determine how much heat content is being absorbed by the evaporator, not its temperature. Temperature is simply a measure of the heat ..., View Full Version : 9 superheat & subcooling scenarios. View Full Version : 9 superheat & subcooling scenarios. nike123. 05-02-2009, 07:28 PM. LOW CHARGE = High superheat. Low suction pressure, indoor TD, subcooling, head pressure & compressor current draw. OVER CHARGE = Low superheat. Normal indoor TD., This thread is in reference to residential split a/c units. I know with a TXV the charge should be checked and/or adjusted according to subcool. If working properly the TXV should pretty much hold the superheat at a constant. But I have seen superheat readings that to me look like the evap coil is being starved. For instance a SH reading above 20 sounds like the charge is low., Which would suggest 26 is high for the superheat and 61 is way high for the subcooling. The suction pressure and SST is normal, but 350 could be high for the head depending on the unit SEER. Residential 13 SEER equipment would be closer to 300 for an 80 degree ambient. It's about right for 10 SEER., I agree, charge with suction superheat on straight cool [only] and then verify the subcooling with a clean-as-new condenser coil. The subcooling changes as the coil ages too. Verify with checking Discharge superheat [apx 100 degrees]. Charging with subcooling only works to get the highest efficiency on High SEER matched system., Which line is the line temp taken and what is the state of the refrigerant for subcool. undercharged. Target is 10 degrees and actual is 5 degrees. Data plate. Where to find subcool target information. Study with Quizlet and memorize flashcards containing terms like Return air wet-bulb temperature and condenser ambient air dry-bulb temperature ..., A subcooling value would be helpful. Reply . 08-02 ... can mask a low charge scenario. The high head leads to poor heat rejection and the higher pressures can force more of the available refrigerant into the evaporator and show up as normal or high suction pressure with normal or low superheat. Also make sure the outdoor fan motor is …, High suction pressure,superheat, and low subcooling. Low suction pressure, low super heat and low subcooling. ... High suction pressure, high superheat, and low subcoomng. 41 of 44. Term. How can moisture in the refrigeration system affect the metering device? contact of the expansion valve bulb. operation of the metering device., Superheat gives us a look at how well we are matching refrigerant flow to heat load. High superheat means evaporator underfeeding; low superheat means overfeeding. There is an issue, though. We could have a correct superheat and still have a coil temperature of under 32°—this is unacceptable in an air conditioning system., always been confused with it .I understand subcool but with superheat it frustrates me since it sounds backwards.With low charge i would expect it to be low superheat since not enough refrigerant to absorb heat.But yet low charge means high superheat but how.If it has low charge or not getting enough refrigerant from the metering device how is it that there is more heat at the suction line ..., If superheat is generated in the suction pipe, then the heat is absorbed from the medium in which the pipe is located (for example ambient air). Advantages. The refrigeration capacity of the system increases with superheating of the vapor, and simultaneously the refrigeration capacity is decreased with the decrease in density …, Step 3. Subtract the evaporator saturation temperature from the thermocouple temperature. This difference is the system superheat. This shows the temperature rise above the bubble point temperature of the system. Review the operating specifications for your system to determine the proper superheat. Inadequate superheat can cause liquid ..., 2 degree drop across drier is acceptable (1-3 degrees in most cases) I-packs run about 17-20 degrees subcool. Superheat should always be monitored, but do not charge by superheat. Do not rely on your site glass to determine charge. You can use it as reference, but a clear site glass does not mean clean bill of health., On traditional HVACR systems, which utilize mechanical metering devices such as a TXV or cap tube, the superheat heating will vary between 8°F to 20°F. On newer systems, which use electronic expansion valves and solid state controllers, it is possible to see the superheat setting as low as 5°F to 10°F., Had a superheat of 2 degrees which seemed very low. Unit upon arrival seemed undercharged as stated. Began doing this when refrigerant was added. Prior to adding refrigerant only had subcooling of 1-2 degrees. Achieved 10 degrees subcooling and began doing this and made the odd noise everytime it reached over 100 degrees saturation on high side., However, the undercharged system will have low subcooling levels. Technicians often confuse an undercharged system with a restricted metering device. ... This will cause the compressor superheat to be high. The 100 percent saturated vapor point in the evaporator will climb up the evaporator coil, causing high superheats. Low Amp Draw, If the superheat is too high and the subcooling is too low, you'll need to add more refrigerant to the system. 4. To do this, attach a charging hose to the system's low-pressure side and open the valve. 5. Slowly add refrigerant to the system until the superheat and subcooling are within the desired range. 6., Your suction gauge is reading too high. Your line clamp thermometer is reading too low. You do not have a good connection on the line, the Schrader core isn't depressing, or the King valve isn't open. A combination of the items listed above. Negative Subcooling . Just as we mentioned above, negative subcooling is actually a superheat condition ..., Study with Quizlet and memorize flashcards containing terms like Subcooling is an important process that ensures _______ refrigerant enters the ________., High subcooling means there is how much liquid? Low subcooling means there is how much liquid?, Subcooling can be defined as: and more., , A low suction superheat does not 'indicate' an overcharge. Low suction superheat is the result of too much refrigerant in the evaporator for the heating loading of the evaporator at that moment in time. Post the startup report data: Outdoor Ambient temperature. Condenser air temp in. Condenser air temp out., By keeping an eye on both subcooling and superheating, you can optimize your refrigeration system’s efficiency, prolong its life, and minimize energy consumption. Navigating through this hub page, you have learned the importance of maintaining the ideal superheat range, as both high and low superheat can cause potential problems in your system., Superheat and Subcooling are technical readings in an HVAC that measure the Freon (refrigerant) reading. Superheat measures the Freon boiling point in gas form while subcooling measures the Freon in liquid form below the evaporation level. To calculate superheat and subcooling measurements, a specific Mathematical chart is used, and the process ..., In summary, here are the seven symptoms or telltale signs of a system low on refrigerant: Medium to high discharge temperatures; High evaporator superheat; High compressor superheat; Low condenser subcooling; Low compressor amps; Low evaporator temperatures and pressures; and. Low condensing temperatures and pressures. Publication date: 7/2/2018., The high head leads to poor heat rejection and the higher pressures can force more of the available refrigerant into the evaporator and show up as normal or high suction pressure with normal or low superheat. Also make sure the outdoor fan motor is running in the proper direction. Reply., And yes, you can have too much subcool, but don't want to since it will, as been talked about before "destroy" the capacity of your system! and will lower the capacity of your condensor. Last edited by Lowrider; 03-03-2007 at 10:05 PM . 04-03-2007, 06:23 AM #15. Gary., What causes Low superheat with high subcool. When both low superheat and high subcooling occur simultaneously, it signals a unique condition that can only be attributed to an overall excess of refrigerant in the system. Overcharging the air conditioning system with refrigerant is the primary cause of experiencing both low superheat and high ...