Running pressures for 410a

In this HVAC Training Video, I Show How to Measure the R-410A Refrigerant Charge Level Using the Subcooling Method. I Check the Charge 4 Times on an Air Cond...

Running pressures for 410a. R-410A systems operate at higher pressures than R-22 systems. Do not use R-22 service equipment or components on R-410A equipment. Service equipment must be rated for R-410A. Inspection As soon as a unit is received, you must inspect it for possible damage during transit. If damage is evident, you must note the extent of the damage on the ...

Anon The compressor is running and producing no pressure it's possible that it's because you've lost the refrigerant charge from the system. On 2020-06-14 - by (mod) - ... I have a 3 ton 410a Lennox with correct suction pressure however my high side pressure is way low. Pressures are 120headover 118 suction low side. What would be the cause.

R-410A Environmental Classification HFC Molecular Weight 72.6 Boiling Point (1atm,°F) -61.0 Critical Pressure (psia) 691.8 Critical Temperature (°F) 158.3 Critical Density (lb./ft^ 3) 34.5 Vapor Density (bp,lb./ft^ 3) 0.261 Heat of Vaporization (bp,BTU/lb.) 116.8 Global Warming Potential (CO2 = 1.0) 2088 ASHRAE Standard 34 Safety Rating A1PROPERTIES R32 R410A Boiling point -51.7°C -51.0°C Critical temperature 78.4°C 72.0°C Saturation pressure at 4°C 818kPa 806kPa Saturation pressure at 40°C 2380kPa 2337kPa Global warming potential 675 2088 Flammability rating A2L lower flammability A1 non-flame propagation Note: R32 systems tend to have a smaller charge size than R410A.We got off easy this year,our highest temp was 128 and been hovering about 120 most of the summer.Last year we had 10 weeks straight with highs about 125. Some of my A/C equipment already hits 350-400 psi range now during the hottest parts of the day.As I understand it the 410 will run 1.6-1.8 times the pressures of 22.This means that the system is always running at a constant known speed and capacity. Most current mini-split systems are VRF (Variable Refrigerant Flow). ... The control board uses temperature and sometimes pressure sensors in a variety of locations in order to control the operation and safeguard the system. ... the R-410A system lists the ...Saturation Pressure-Temperature Data for R410A (psig)*. Temp (°F) Pressure. Temp (°C) Temp (°F) Pressure. Temp (°C) Temp (°F)As an HVAC technician or someone interested in air conditioning systems, understanding the key factors that impact 410A refrigerant pressures is crucial. The proper functioning of ...

R410A PRESSURE-TEMPERATURE CHART. Saturation Pressure-Temperature Data for R410A (psig)*.The pressure of R-410A is so high that if your hand gets in the way of a leak, it could cut a finger off. This is a myth, as well as a physical impossibility. Devices such as insulin jet injectors require 7,000 to 10,000 psi pressures to puncture the skin and 16,000 to 25,000 psi pressure spikes are normally used.Remove the cap to the low pressure line (Usually the only port). Check the gauges and be sure the valves are turned off (clockwise). Connect the gauges center yellow hose to the R410a refrigerant tank. Connect the adapter to the blue low pressure line on the gauges. As quickly as possible, attach the blue hose with the adapter to the mini split ...The normal pressure for a typical R-401A mini-split ranges from 110-140 psi. However, keep in mind that the working pressure depends on factors like cooling load and weather. According to experts, the working pressure should never be less than 100 psi or more than 160 psi.Pressure Range Low side: 36 to 50 psi High side: 284 to 356 psi Indications Both pressures are TOO HIGH The low-side piping is not cold Causes Air in the system Remedy Evacuate the system Replenish the refrigerant Check the gauge readings If prolonged operation with air in the system, the liquid tank must be replaced.

Low-pressure switches on Carrier equipment using R-410A are usually set to open at about 50 psi and close at about 100 psi. Note: Heat pumps operating in the heating mode also may have a vapor switch that cycles the outdoor fan when the pressure is about 400 psi, and resets when the pressure drops to about 310 psi.Forane 407C Pressure Temperature Chart. Saturation Pressure-Temperature Data for R-407C (psig)*. Temp. ( F) Pressure Liquid Vapor. Temp. ( C)This script determines the gas pressure based on temperature of R410a refrigerant. R410A is an HFC refrigerant, invented by Honeywell, that has been developed to replace the HCFC refrigerant R22. Systems operating on R410A run at a pressure of about 1.6 times that of similar systems operating on R22. Energy efficiency is comparable to R22.5.1.2 Heating Operation. Constant evaporating temperature (Te) control Basic target value: R22 = 115°F (46°C), R407C = 118°F (48°C), R410-A = 115°F (46°C) *Compensation is applied. Constant superheated degree (SH =Ts-Te) control Basic 9°F (5°C) compensation is applied.

Qt everman parkway.

R-410A Environmental Classification HFC Molecular Weight 72.6 Boiling Point (1atm,°F) -61.0 Critical Pressure (psia) 691.8 Critical Temperature (°F) 158.3 Critical Density (lb./ft^ 3) 34.5 Vapor Density (bp,lb./ft^ 3) 0.261 Heat of Vaporization (bp,BTU/lb.) 116.8 Global Warming Potential (CO2 = 1.0) 2088 ASHRAE Standard 34 Safety Rating A1R410A should be tested as follows well accodring to my gas safe handling book from college, Minimum allowable pressure for design and leak testing is 33.6 bar or 504psi. Strength test pressure x1.3 allowable ps is 43.68bar or 655psi.** 87.8°F is the Critical point of CO2, Pressure 1056.2 psig. Distinct liquid and vapor states do not exist. **** 31.1°C is the Critical point of CO2, Pressure 72.82 bar.R-410A. R-32. Formula. R-32 (68.9%) R-1234yf (31.1%) R-32 (50%) R-125 (50%) CH₂F₂. Molecular weight, (g/mol) 62.61. 72.6. 52. Boiling temp, ˚ F (˚ C)-58.9 ( …Discharge pressures are lower than R-410A, while discharge temperatures are higher, but this increase is not great enough to pose a concern. Because it operates at temperatures and pressures similar to those of R-410A, switching to R-454B should be a relatively easy transition. Carrier has done extensive modeling and testing with our compressor ...

Both older R-22 and R-134 operate at lower pressures than R-410A. R22 Refrigerant Pressure Rules of Thumb Typical Off, Low, High side R22 Pressures & Temperatures. On a properly-charged and working air conditioning system using R-22 refrigerant. Low pressure refrigerant switches on Carrier HVACR typically open at 50 psi and close at 100 psi. R454B vs R410A: Cost Comparison. Let's talk money. Because let's face it, cost is a big factor in any decision. Purchase Price. R410A is typically cheaper to buy initially, but remember - cheaper isn't always better in the long run. Maintenance and Operation Costs. While R410A may be cheaper upfront, R454B could save you money over time.i just installed a new split unit r-410a a/c system. it is running at 285/120 psig. the high side seems way low, should be about 420. the correct orifice is installed. this is a 1.5 ton condenser, 2 ton evaporator, and a 0.051 inch orifice. thanks for any suggestions. hvac.Determire. •. (90-92F outside, 76-77F inside) The AC works ok but has difficulty cooling below 75F. temp at air filter around 78-80 with discharge air about 63-65. Time for a service call. System is underperforming. Reply. Im measuring mine around 80F after the system runs for a bit (90-92F outside, 76-77F inside), which from what ive read is ...If the air conditioning isn't blowing cold air and the low side pressure is too high, it could be caused by issues with the condenser fan. However, there's also the possibility that the system has been overcharged with too much refrigerant. 1. Defective Condenser Fan. When the fan becomes damaged, airflow through the condenser is diminished.00:00 - What are normal pressures for R410A?00:37 - Can you pump down a 410A system?01:04 - What should my gauges read on 410A?01:39 - Can you put R22 in a R...Forum Rules. I have a 3Ton Carrier Heat Pump unit using 410A that has extremely high suction pressure around 250PSI. I also have a low liquid line pressure around 300PSI and my sub-cooling is around 40-50 Degrees. I have checked for a stuck liquid line solenoid but this system does not have one, and I checked the reversing valve and its ...What are normal operating pressures for R134a? The normal running pressure of R134A is between 22 and 57 psi. What is the pressure of AC gas? If using AC refrigerant R-22, a 1.5 ton AC should ideally have the pressure between 65 and 70 PSI. For 1 ton AC, the AC gas pressure will be 60 to 65 PSI. What should 410A pressure be at 90 degrees? R ...I thinks your assuming it was low because of suction pressure. If TXV Charge to sub cooling-- I am thinking your sub cooling was high and you have a restriction or TXV issue. Good point, the stuck TXV would be known by high subcool and high superheat. This would be a tough diagnosis for a beginner tech.

Post Likes. 410A TXV Troubleshooting. I am a fairly new tech so bare with me, went to a service call earlier today for no cooling on a 410a system. Air filters were clean, so went upstairs in the attic to find that the TXV was frozen over and the indoor coil was frost over some. The Blower was running great as it was passing thru the coil.

Sep 17, 2017 · Heating mode: outside temp >65F: Run AUX only - lock out compressor (avoid high pressure) outside temp >10F and <65F: Run compressor and AUX as needed. outside temp <10F: Run AUX only - lock out compressor (avoid defrost cycling) Cooling mode: outside temp <60F: lock out compressor, run air handler fan only. Hi all. I have a question regarding the 410A systems and there related pressures. I am quite familiar with R22 and the proper pressures associated with their proper function but am not nearly as familiar with the newer systems. ... If I walked up to a running unit with those pressures I would check the temperature of the suction line first to ...5 Refrigeration Troubleshooting Form. Download this manual. See also: Owner's Manual. INSTALLATION, OPERATION. & MAINTENANCE MANUAL. R-410A Water-to-Water Series: HWW Water-Source Heat Pumps. Heat Controller, Inc. • 1900 Wellworth Ave. • Jackson, MI 49203 • (517)787-2100 • www.heatcontroller.com. Table of Contents.Yes it will more than likely have a low pressure and high pressure cut off switch to prevent damage to the compressor. Reply. Floyd HVAC says. August 3, 2017 at 4:27 pm ... Question my ac unit will shut down but my fernece fan keeps running what's causing the problem. Reply. Villie Frank says. June 18, 2018 at 1:38 pm ...R-410A compatibility offered with P266SNR-2C transducer. PRODUCT. SWITCH ... Pressure PSI. Typical Applications. V246 Series 2-Way Pressure-Actuated Water- ...AC compressors made to use R-410A are therefore able to withstand more stress without the likelihood of cracking. That is why if you were to put R-410A in an R-22 AC unit the system would just rupture due to the high pressure. Recharging/Top Off. Most people are familiar with the process involved when an air conditioner running on R-22 leaks. ™ 410A Refrigerant (R-410A) 0 0 20 40 60 80 Temperature (°F) 100 120 140 R-22 R-410A 100 200 300 400 500 600 700 Product Information Freon™ 410A is a non-ozone depleting high efficiency hydrofluorocarbon (HFC) refrigerant. Freon™ 410A has higher cooling capacity and operating pressures than R-22 for new equipment specifically designed ...

Free railroad ties'' craigslist.

Puerto rican taper fade.

To satisfy industry regulations, the HVAC industry is transitioning from Puron (R-410A) refrigerant to Puron Advance (R-454B) by the year 2023. We talk about the implications for homeowners. Unless you work in HVAC (Heating, Ventilation, and Air Conditioning), you probably won’t need to know what R-454B refrigerant is, or why it’s a big deal.Absolutely there is pressure in the air conditioning or heat pump system when the compressor is not running. When the compressor shuts off the high side pressure is high - say 200 and the low side low - say 20 (these are just conceptual as actual pressure depends on the compressor, ambient temperature, refrigerant type).i just installed a new split unit r-410a a/c system. it is running at 285/120 psig. the high side seems way low, should be about 420. the correct orifice is installed. …Hi All, I just had a new Goodman 16 seer R410A heat pump system installed (SSZ160241AE outdoor unit, AEPF313716AA air handler). It seemed to work fine when the installer left but almost immediately, the outdoor unit started to run intermittently when in heat mode. I'm mechanically inclined and poked around a bit, enough to determine that the high pressure switch was tripping.R410A Pressure-Temperature Chart Liquid. Vapor: Liquid: Vapor Liquid: Vapor Liquid: Vapor-49; 5.5; 5.4-45 1: 49.7 49.5-17.2 51: 145.8 145.2: 10.6 101: 323.1 322.1: 38.3-48; 6 5.9-44.4 2; 51.1 50.8 ... Pressure Temp (°C) Temp (°F) Pressure Temp (°C) Temp (°F) Temp (°C) Pressure Temp (°F) Pressure Temp (°C) Created Date:One such substitute that has gained widespread acceptance is R410A, a hydrofluorocarbon (HFC) blend. Unlike R22, R410A does not contribute to ozone depletion and has a lower GWP. This makes it an attractive choice for manufacturers who want to comply with environmental regulations while maintaining the efficiency and performance of HVAC systems.Pressure Range Low side: 36 to 50 psi High side: 284 to 356 psi Indications Both pressures are TOO HIGH The low-side piping is not cold Causes Air in the system Remedy Evacuate the system Replenish the refrigerant Check the gauge readings If prolonged operation with air in the system, the liquid tank must be replaced.So they say to only charge 410a as a liquid. Scenario: guy at at work recovers 5.8lbs of 410a into vacuumed recovery cylinder. Then, in order to get only liquid back in, uses the recovery machine in reverse to charge. ... Normally if system is running you can use the compressor to suck the refer in through the low side. With 410a I only do 6-8 ...Typically, for a properly charged R-410A system, the low-side (suction) pressure may range from 120 to 150 psi, and the high-side (discharge) pressure may range from 300 to 450 psi, depending on factors such as temperature and load. What is the pressure at 100 degrees on 410A? ….

What is the suction pressure of a Mitsubishi R410a? Normally R-22 operating system typically have a high-side (discharge) pressure of 260 psig and low-side (suction) pressure of 76 psig, while a normally R-410A operating system have a high-side (discharge) pressure of 418 psig and low-side (suction) pressure of 130 psig at 45°F/7.2℃. Refrigerant Pressure-Temperature Home Back. Choose Refrigerant: R-410A R-22 °C °F: Psig-40-39-38-37-36 ... Cans of R134a: https://amzn.to/3NLEJbr1/4" Can Adapters: https://amzn.to/3XKGL04New R1234yf Refrigerant: https://amzn.to/44xBxa3Gauges for Both Old & New Ref...Critical Pressure (psia) 691.8 Critical Temperature (°F) 158.3 Critical Density (lb./ft^ 3) 34.5 Vapor Density (bp,lb./ft^ 3) 0.261 Heat of Vaporization (bp,BTU/lb.) 116.8 Global Warming Potential (CO2 = 1.0) 2088 ASHRAE Standard 34 Safety Rating A1 Refrigerant Boiling Point Physical Properties Refrigerant -80°F -40°F 0°F 40°F 80°F 120°F ...6 Nov 2023 ... What Should my AC Pressures Be for R410A Refrigerant. Benjamin Sahlstrom ... R-22 and R-410A Operating Pressures on Air Conditioners! Checking ...Head on 410 at 100° will be in the 375 - 400 range depending on surrounding conditions, sun, heat load inside, dirt on the coil. high suction pressure could be from a high load, bad compressor, bad-wrong-nonexistant metering device. There are a multitude of things that can cause pressures to be high or low depending on the situation.The unit was charged in heating mode and 11lbs 1 oz of refrigerant was used. When the heat pump is running it blows semi-warm air like it is operating correctly but when I put my gauges on the system the high side pressure was 425 and low side was 395-400.and a temperature sensor, and externally by the system high and low pressure switches. • Reliable operation - Ball bearing fan motors provide superior performance in extreme temperatures. • Environmentally friendly - CFC-free R-410A refrigerant delivers environmentally friendly performance with zero ozone depletion.R410A Systems Run at a Different Pressure. Compared to an R22 system, an R410A air conditioner runs at a higher pressure. These systems operate at about 130 pounds per square inch (psi). In AC mode, an R22 evaporator coil will run at about 70 psi. Therefore, newer systems run at nearly double the pressure, assuming they’re …The high-side saturation pressure is 365 psig and the unit's technical manual specifies 10°F of liquid subcooling. What would the desired liquid-line temperature be at the outlet of the condensing unit? 100°F. A technician is working on an R-404A refrigeration system and determines that the head pressure is 205 psig and the condenser outlet ... Running pressures for 410a, psig °f psig °f psig °f psig °f psig °f 12; -37.7. 114, R-22 has been the most widely used refrigerant for many years but was phased out in 2020 due to its ozone depletion potential. Meanwhile, R-410A is an alternative that provides better performance and efficiency than its predecessor while not degrading the ozone layer. The primary difference between them is their compositions; specifically, R-22 ..., November 2, 2003. Several major manufacturers are producing comfort air conditioning equipment using refrigerant 410A. The trend towards the use of R-410A continues to grow and there is a demand for technicians who are comfortable working with this higher-pressure replacement for refrigerant 22. Due to the differences between R-22 and the newer ..., 18 Apr 2017 ... In this HVAC Refrigerant Charging Video I go over what it means to have low R-22 Freon or Low R-410A Suction Vapor Pressure along with a Low ..., The unit was charged in heating mode and 11lbs 1 oz of refrigerant was used. When the heat pump is running it blows semi-warm air like it is operating correctly but when I put my gauges on the system the high side pressure was 425 and low side was 395-400., R-22 air conditioners use mineral oil and R-410A systems use synthetic oil. The synthetic oil is generally more soluble with R-410A than mineral oil is with R-22. This means the R-410A system operates more efficiently reducing wear and tear on the compressor. Dry Charging., Btenaircool Services January 03, 2018 No comments. R-22. Standing pressure - 150 PSI. Saction pressure - 60 TO 70 PSI. Discharge pressure - 250 TO 300. R-410A. Standing pressure - 260 PSI. Saction pressure - 120 TO 130 PSI. Discharge pressure - 450 TO 500., psig °f psig °f psig °f psig °f psig °f 12; –37.7. 114, Technical. Guidelines. Available in the following sizes. R-410A 25LB. CYLINDER 100 LB. CYLINDER 850LB. CYLINDER 1450 LB. Pressure-Temp Chart. R-410A. (R-32/125) (50 …, Appropriate Heat Pump Pressure Readings. I understand and respect the rules about describing the technique for using refrigerant on the forum. I am NOT interested in messing around with the refrigerant in my new Carrier, Infinity heat pump. That being said, I have many years experience with automotive AC and was involved in research and ..., Table 1 compares pressure drops in temperatures and pressures for several common refrigerants. Note that the refrigerants have different pressure drops for the same change in temperature. For example, many documents refer to acceptable pressure drop being 2°F (1.1°C) or about 3 PSI (20.7 kPa) for R-22. The same 3 PSI change in R-410A, results, This means that the system is always running at a constant known speed and capacity. Most current mini-split systems are VRF (Variable Refrigerant Flow). ... The control board uses temperature and sometimes pressure sensors in a variety of locations in order to control the operation and safeguard the system. ... the R-410A system lists the ..., Break the vacuum on the system and supply liquid R-410A to the liquid line or receiver port. Weigh in the initial charge and ensure a proper vacuum was achieved. Adjust sensors or set points to operate the compressor continuously while charging the system. Add refrigerant to allow the discharge pressure to rise to 325-420 psig., We find in industry, that a large percentage of air conditioning systems are still running on R22, of course all of the new systems are now running with R410a. ... R410A saturated vapour pressure is approximately 60% higher than that of R22. The composition of the refrigerant and the increased pressures necessitate R410A dedicated tools and ..., What is an R410A PT Chart? An R-410A Pressure-Temperature (PT) chart is a tool used in HVAC systems to determine the corresponding saturation temperature of the R-410A refrigerant at different pressures. This chart is essential for HVAC technicians as it helps in diagnosing and maintaining air conditioning systems., In one of the last experimental studies with the blends DR-55 and DR-5A, Sieres et al. [38] observed that these alternatives for R-410A presented a similar pressure ratio with the baseline refrigerant, but with lower suction and discharge pressures for the same operating conditions. The highest optimum charge, calculated to maximize the system ..., Using the temperature rise method (CFM = KW (Volts X Amps) X 3.413 divided by (Temp rise X 1.08)), check the airflow. Using the manufacturer's coil specification sheets, confirm the pressure drop across coils. The airflow measurement is used to find the evaporator load, so it must be accurate. Check the system operating pressures., TEMPERATURE - PRESSURE CHART FOR R-22, R-410A, R-407C, R-134A & R-404A REFRIGERANTS FYI #289 9/17/2009. updated 10/10/2012. Data points are reproduced based on available information. Advantage assumes no responsibility or liabililty for data errors. ADVANTAGE Engineering, Inc. 525 East Stop 18 Road Greenwood, IN 46142 317-887-0729 fax: 317-881 ..., Step 2. Connect the yellow hose on the manifold gauge to the 410A refrigerant tank. Turn the handle on top of the tank to release refrigerant from the tank. Flip the tank upside down so that it will charge the system in a liquid state., Constants for vapor pressure of saturated vapor (dew point), p g: A = -1.440004 E+00 E = -3.521484 E+00 B = -6.865265 E+00 F = -7.750000 E+00 C = -5.354309 E-01 X o = 2.086902 E-01 D = -3.749023 E+00 Because both pressure and temperature appear in the reduced form in the equation, the same constants can be used for either SI or ..., If the pressure you are getting is down 10-15%, you probably need more refrigerant. Consult your user's manual to be sure or call Gree Electric Appliances, Inc. of Zhuhai. Second, you are looking at a heat pump. Verify the system is in cooling mode. IRstuff (Aerospace) 6 Jul 17 18:16., What is the standing and discharge pressure of a refrigerant? Refrigerant pressure readings R-22, R-410A, R-290, R-417A 1 Standing pressure – 150 PSI 2 Saction pressure – 60 TO 70 PSI 3 Discharge pressure – 250 TO 300. Freon gas standing and working pressure ( R32, R410A, R502,R407C, R134A etc ), Warning: Do not attempt to troubleshoot refrigerant charge on central air conditioning units unless you are EPA 608 type II Certified. This article refers to troubleshooting refrigerant charge on 410a and R22 residential air conditioning systems. Although many of the principles will carry over to other types of refrigerants and drop-ins. I will be sharing a …, If the air conditioning isn't blowing cold air and the low side pressure is too high, it could be caused by issues with the condenser fan. However, there's also the possibility that the system has been overcharged with too much refrigerant. 1. Defective Condenser Fan. When the fan becomes damaged, airflow through the condenser is diminished., The picture below shows a system running on a 85°F day that had 6 ounces of R-410A added. In the picture, the manifold valve to the blue hose is closed so the blue gauge is measuring the pressure inside the running system. The vapor pressure is 118 PSIG and because it is 85°F outside, the R-410A bottle pressure is 254 PSIG., Operating an air conditioner for extended periods of time in low temperatures outdoors lowers the suction pressure to a velocity where the oil will not return to the compressor and will run dry. Also, under low ambient conditions “indoors” does not provide sufficient load to change refrigerant from a liquid to a 100% vapor., SUBJECT: TEMPERATURE - PRESSURE CHART FOR R-22, R-410A, R-407C, R-134A & R-404A REFRIGERANTS FYI #289 9/17/2009. updated 10/10/2012. Data points are …, very high condenser pressures compared to the R22 (R22: 43 °C, 15.8 bar; R410A: 42 °C, 26 bar) prevent the conversion of older sys-tems to R410A refrigerant. Because all components such as com-pressors, liquefiers, collectors, evaporators, piping, etc. must all be designed or developed to withstand these high pressures., The running pressure is about 200 on the fluid line and 150 on the exhaust line. What are normal operating pressures for R-410A? A normally operating R-410A system with the same condensing temperature of 120 degrees and a 45 degree evaporator saturation temperature will have a high side pressure of 418 psig and a low side pressure of 130 psig., What is an R410A PT Chart? An R-410A Pressure-Temperature (PT) chart is a tool used in HVAC systems to determine the corresponding saturation temperature of the R-410A refrigerant at different pressures. This chart is essential for HVAC technicians as it helps in diagnosing and maintaining air conditioning systems., Pressures: R22 vs 410A. The operating pressures of R22 and 410A are different, which affects how air conditioning systems are designed and function. R22 Pressure: R22 operates at lower pressures compared to 410A. This means systems designed for R22 cannot handle the higher pressure of 410A without modifications., A normally operating R-410A system with the same condensing temperature of 120 degrees and a 45 degree evaporator saturation temperature will have a high side …, May 26, 2012 · Head pressure: 118F 83 + 35 = 118F more or less shows on the high side gauge if I understand this correctly. Low side pressure: 125 psi = 42 saturation temp. 66.2 low side line temp. High side pressure: 335psi = 104 saturation temp. 83.1 high side line temp. Temp at the vent in rooms: 56.1F + or minus. Temp from supply side: 55.2F.